Power-Supply (Selectable) |
110V or 220V AC, 50/60 Hz |
Power Consumption |
9VA |
Line Filter |
Built-in |
Load Cell Type |
All strain gauge type |
Load Cell Supply |
10V DC, 150mA, reduces to 120mA with 4-20mA output option (4x 350Ω, 8x 700Ω load cells) |
Input Sensitivity (Selectable) |
0.5µV/D to 200µV/D max. 20mV input |
Hi/Lo or Control Output* |
Optp-coupled 80V DC max 0.3A |
Zero adjustment range |
0.05mV - 15mV |
Scale range |
500 ~ 100,000 |
Step Width |
1, 2, 5, 10, 20 or 50 |
Maximum Display Resolution |
10,000 divisions |
Display |
13mm LED display (6 digits) |
Display Up-Date Rate (Selectable) |
1, 4, 8, 16 or 20 per second |
|
BCD* Output Rate (Selectable) |
4, 8, 16, 20, 60, 80 or 100 |
RS232/RS485 Port* |
Bi-directional, 2400, 4800, 9600 or 19200 baud 7 data bit, even parity,1 stop bit |
Units |
kg/t selectable |
Relative Humidity |
90% Non-condensing |
Operating Temperature Range |
-5 ~ 50°C (23 ~ 122°F) |
Temperature Coefficient |
8ppm / °C of FSD |
Non-linearity |
0.005% FSD |
Dimensions |
144mm(L) x 96mm(W) x 48mm(H) |
Conversion Rate |
200 times/second (max) |
Internal Resolution |
16,700,000 |
Supplied Accessories |
Instruction Manual |
Net Weight |
450gms approx |
Analogue Output* |
0-5V, 4-20mA, 0-20mA |
(* Options purchased separately) |
|
|